Open Access
Table 9
Solar module variables for New Mexico with all electric characteristics.
| New Mexico all electric − variable | Carport PV | Floating PV [53,54] |
|---|---|---|
| Module [$/WDC] | 3.5 | 0.33 |
| Inverter [$/WDC] | 0.03 | 0.04 |
| BOS [$/WDC] | 0.56 | |
| Installation Labor [$/WDC] | Included in Module [55,56] | 0.06 |
| Installer Margin and Overhead [$/WDC] | 0.02 | |
| Contingency [%] | 3 | 5.4 |
| Permitting and Environmental Studies | 0.01 [$/WDC] | 9.1% |
| Engineering and Developer Overhead [%] | 0.02 [$/WDC] | 19.85% |
| Grid Interconnection [$/WDC] | 0.02 | 0.09 |
| Land Perp. And Transmission [$/kWDC] | 0.02 | 0.02 |
| O&M Cost [$/kWDC/Year] | 19 | |
| ITC (%) | 40 |