Open Access
Table 5
Technical feasibility for traditional and all electric characteristics.
| State | Detention basin area available [m2] | Land area required for estimated solar PV capacity for community with traditional characteristics [m2] |
Percentage of detention basin area required for community with traditional characteristics [%] |
Technically feasibility for community with traditional characteristics [Yes/No] |
Land Area required for estimated solar PV capacity for community with all electric characteristics [m2] |
Percentage of detention basin area required for community with all electric characteristics [%] |
Technically feasibility for community with all electric characteristics [Yes/No] |
|---|---|---|---|---|---|---|---|
| Texas | 6,172 | 9,210 | 149 | No | 6,447 | 104 | No |
| Oklahoma | 87,464 | 373,684 | 427 | No | 143,947 | 164 | No |
| New Mexico | 40,672 | 41,052 | 101 | No | 21,315 | 52 | Yes |
| Louisiana | 46,623 | 18,947 | 40 | Yes | 9,737 | 21 | Yes |
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.