Open Access
Table 2
Specifications of instruments used in the study.
No. | Name and model | Manufacturer | Sensitivity value/instrument type | Measurement range/accuracy |
---|---|---|---|---|
1 | Eppley Black and White Pyranometer Model 8-48 | Eppeley Laboratory, Inc. | 10.08 µV/W/m2 | –20 °C to +40 °C |
2 | Wind101A System (3 cup anemometer and data logger) | MadgeTech | 1 Pulse/ 0.655m/s | 1.5 MPH to 100 MPH |
3 | T-C 08 Thermocouple Data Logger | Pico Technology Limited | N/A | –270 °C to +1820 °C, ±50 mV, ±500 mV, ±5 V and 4–20 mA for the single channel terminal board |
4 | K-Type Thermocouples | Guangzhou Logoele Electronics Technology Co., Ltd | K − Special Limits | –270 °C to +1260 °C |
5 | Microwave | Panasonic | N/A | 0 °C to 200 °C |
6 | Analog Measuring Scale | Salter Housewares | N/A | Maximum of 100 kg |