Table 4

The analysis of variance results for effects of roof angle, inlet gap size, and dryer height on temperature.

Source DF Adj SS Adj MS F-Value P-Value
Model 33 490.403 14.8607 299.49 0.000
Linear 9 476.867 52.9852 1067.80 0.000
Height (cm) 5 380.850 76.1701 1535.05 0.000
Roof Angle (deg) 2 5.846 2.9231 58.91 0.000
Inlet Gap(mm) 2 90.170 45.0850 908.59 0.000
2-Way Interactions 24 13.536 0.5640 11.37 0.000
Height (cm) * Roof Angle (deg) 10 1.522 0.1522 3.07 0.016
Height (cm) * Inlet Gap(mm) 10 11.808 1.1808 23.80 0.000
Roof angle (deg) * Inlet Gap(mm) 4 0.205 0.0514 1.03 0.414
Error 20 0.992 0.0496
Total 53 491.395

Degrees of freedom = DF, sum of squares = SS, mean squares = MS, F – ratio of variance of a source to variance of error, determines significance at 95% confidence level = P < 0.05.