Table 5

Calculation of thermal bridges (Scenario 2 and Scenario 3 proposals “b” and “c”).

  Thermal bridge Ψ (W/MK) Condensation risk
SCENARIO 2 TB1 0.5209 None
  TB 2 0.6658 None
  TB 2 B) 1.1065 None
  TB 3 0.4547 None
  TB 3 B) 0.817 Yes
SCENARIO 3 PROPOSAL “B” TB 0.1 0.872 None
  TB 0.2 0.267 None
  TB 0.2 B) 0.249 None
  TB 0.3 1.1238 Yes
  TB 0.3 B) 0.5504 None
  TB 1 –1.6531 None
  TB 2 0.6516 None
  TB 2 B) 0.7939 None
SCENARIO 3 PROPOSAL “C” TB 0.1 –0.1407 None
  TB 0.2 0.0646 None
  TB 0.2 B) 0.934 None
  TB 0.3 1.7929 None
  TB 0.3 B) 0.3239 None
  TB1 0.472 None
  TB2 0.2535 None
  TB2 B) –0.1817 None

TB: Thermal Bridge.