Open Access
Review

Table 1

Measurement input data and experimental results for the thermal conductivity of various samples.

  Test e s (cm) U (V) Re (Ω) T 0 (°C) T 1 (°C) T 2 (°C) λ (W/m.K)
Pure plaster 1 3.02 14.157 37.89 32.779 21.923 20.735 0.523
2 33.908 22.969 21.873 0.519
3 34.654 23.724 22.658 0.520
Mean value of thermal conductivity (W/m.K) 0.520
Standard max deviation (%) 0.6
P+2% WCF 1
2
3
3.22 14.101 37.89 40.167 27.360 27.600 0.445
36.413 23.884 23.037 0.445
37.403 25.484 23.862 0.466
Mean value of thermal conductivity (W/m.K) 0.452
Standard max deviation (%) 3.1
P+3% WCF 1 3.22 14.101 37,89 36,523 23,865 21,437 0,421
2 39,073 25,861 23,905 0,403
3 35,78 22,809 21,602 0,420
Mean value of thermal conductivity (W/m.K) 0.415
Standard max deviation (%) 2.9
P+4% WCF 1 3.24 14.101 37.89 37.656 23.663 22.853 0.386
2 39.001 24.595 23.665 0.370
3 37.322 23.293 23.983 0.401
Mean value of thermal conductivity (W/m.K) 0.386
Standard max deviation (%) 4.1
P+5% WCF 1 3.40 14.101 37.89 39.042 23.809 23.526 0.365
2 40.235 24.774 24.746 0.360
3 40.696 25.281 25.426 0.364
Mean value of thermal conductivity (W/m.K) 0.363
Standard max deviation (%) 0.8