Open Access
Table 1
Input parameters used for estimating the annual useful thermal energy delivered and corresponding LCUTE for SIPH system and LCUTE for conventional process heating system.
Parameter | Symbol | Unit | Description | Reference(s) |
---|---|---|---|---|
(A) LCUTE of conventional process heating system | ||||
Capital cost | C0 | Rs. | 7,000,000 | – |
Useful life | n | Years | 30 | [11,12] |
Calorific value of furnace oil | MJ/kg | 43.5 | ||
Efficiency of fuel utilization in the boiler | – | % | 0.75 | |
Price of furnace oil (2016) | – | Rs. | 28 | [13] |
Discount rate | d | % | 12 | |
(B) Parameters for estimating and LCUTE of solar industrial process heating system | ||||
Process heating requirement | PHRh | GJ | 1.52 | – |
Performance equation (parabolic trough collector) | η = 0.71 – 0.3581 * (Tm−Ta)/I − 0.0019 * (Tm−Ta)2/I | [14] | ||
Solar collection area | – | m2 | 942 | – |
Cost of solar collector and other components | – | Rs./m2 | 26,500 (including 18,000/m2 as solar collector cost) | [5] |
Thermal energy storage cost | – | Rs. | 2,993,188 | – |
Capital cost of SIPH system | C0 | Rs. | 27,956,188 | – |
Useful life | n | Years | 25 | [15] |
Annual operational cost | ACO | % | O | |
Annual maintenance cost | ACM | % | 1% of capital cost | |
Annual escalation in operation and maintenance cost | £ | % | 1% per year | |
Annual duration in performance | – | % | 0.005 | – |
Discount rate | d | % | 12 | – |