Appendix A

Dwelling characteristics and occupancy.

House Year built Typology Floor area (m2) Design Technologies NatHERS/description
A 2009 Detached house 177 Double brick walls; concrete slab; R3 ceiling insulation; R1.5 roof insulation; North orientation. 1.2 kW PV system; solar hot water with gas booster 8.5 Star
B 1950 Detached house 106 Timber frame walls with R2 insulation; R2.5 ceiling insulation; suspended timber floor with R1.5 insulation; North orientation. 1.5 kW PV system; solar hot water with electricity booster Retrofitted
C 1899 Detached house 106 Limestone and double brick walls; suspended timber floor and concrete slab; R3.5 ceiling insulation; R1.5 roof insulation; South-East orientation. 1.68 kW PV system; solar hot water with electric booster Retrofitted
D 1920 Detached house 183 Double brick and timber frame walls with R3.5 insulation; concrete and suspended timber floor; R3 ceiling insulation; R1.5 roof insulation; North orientation. 1.1 kW PV system; solar hot water with gas booster Deemed-to-satisfy
E 2011 Strata complex 186 Rammed earth and insulated panel walls with R2.5 insulation; concrete slab; R3 ceiling insulation; R2.5 ceiling insulation; North orientation. 2 kW PV system; instantaneous gas water heater 7 Star
F 2011 Detached house 238 Rammed earth and double brick walls with R2.5 insulation; concrete slab; R3 ceiling insulation; R2.5 roof insulation; North orientation. 2.28 kW PV system; solar hot water with electric booster 8 Star
G 2013 Detached house 218 Double brick walls; concrete slab; R4 ceiling insulation; West orientation. Solar hot water; with electric booster 6 Star
H 2013 Detached house 147 Double brick walls; concrete slab; R3 ceiling insulation; North orientation. 2.66 kW PV system; solar hot water with gas booster 6 Star
I 2013 Detached house 154 Double brick walls; concrete slab; R4 ceiling insulation; North orientation. 1.8 kW PV system; solar hot water with gas booster 6 Star
J 1901 Detached house 177 Timber frame walls with R2 insulation; concrete and suspended timber floor; R4.5 roof insulation; South orientation with North facing clerestory. 3.5 kW PV system; instantaneous gas water heater 6 Star