Parameters Unit Value
PV Module Rated capacity kW 1.04
Capital cost $ 5000
Replacement cost $ 3400
Operation and maintenance cost $/year 20
Lifetime year 25
Batteries Nominal voltage Volt 12
Nominal capacity Ah (kWh) 100 (1.2)
Minimum state of charge % 30
Capital cost $ 180
Replacement cost $ 180
Operation and maintenance cost $/year 5
Minimum battery life year 4
Quantity 6
Converter Rated capacity kW 2.5
Efficiency % 94
Capital cost $ 1500
Replacement cost $ 1500
Operation and maintenance cost $/kW/year 10
Lifetime year 10
Diesel generator Rated capacity kW 3.5
Capital cost $ 1450
Replacement cost $ 1300
Operation and maintenance cost $/h 0.3
Life time operating h 10,000
LPG generator Rated capacity kW 3.5
Capital cost $ 1150
Replacement cost $ 1050
Operation and maintenance cost $/h 0.2
Life time operating h 12,000