Open Access
Table 1
Technical parameters and cost of components.
Parameters | Unit | Value | |
---|---|---|---|
PV Module | Rated capacity | kW | 1.04 |
Capital cost | $ | 5000 | |
Replacement cost | $ | 3400 | |
Operation and maintenance cost | $/year | 20 | |
Lifetime | year | 25 | |
Batteries | Nominal voltage | Volt | 12 |
Nominal capacity | Ah (kWh) | 100 (1.2) | |
Minimum state of charge | % | 30 | |
Capital cost | $ | 180 | |
Replacement cost | $ | 180 | |
Operation and maintenance cost | $/year | 5 | |
Minimum battery life | year | 4 | |
Quantity | – | 6 | |
Converter | Rated capacity | kW | 2.5 |
Efficiency | % | 94 | |
Capital cost | $ | 1500 | |
Replacement cost | $ | 1500 | |
Operation and maintenance cost | $/kW/year | 10 | |
Lifetime | year | 10 | |
Diesel generator | Rated capacity | kW | 3.5 |
Capital cost | $ | 1450 | |
Replacement cost | $ | 1300 | |
Operation and maintenance cost | $/h | 0.3 | |
Life time operating | h | 10,000 | |
LPG generator | Rated capacity | kW | 3.5 |
Capital cost | $ | 1150 | |
Replacement cost | $ | 1050 | |
Operation and maintenance cost | $/h | 0.2 | |
Life time operating | h | 12,000 |